Telephone
025-52791167,52791168
13390905858
13390905858
TESCOM regulating valve 26-1200
High flow Cv=3.3, 6.0 or 12.0
Maximum inlet pressure 6000 PSIG/Load external gas outlet pressure can reach maximum inlet pressure
Mouth pressure value/No exhaust valve/Reduced pressure
26-1200 series
technical specifications
Operating parameters
Pressure rating according to ANSI/ASME B31.3 standard
Maximum rated inlet pressure 4000&6000 PSIG
Export pressure To the maximum inlet pressure value
Design test pressure Maximum rated pressure 150%
Leakage No gas leakage
Rated flow rate Cv=3.3, 6.0 or 12.0*
*The secondary pressure drop caused by the outlet cross hole will have a significant impact on the rated flow rate.
For flow curve data when the outlet pressure is less than 1000 PSIG, please contact the engineer
Factory consultation.
Materials in contact with the medium
Valve body 303, 316 stainless steel, or 2024-T351 aluminum
Valve seat CTFE or Vespel ®
Partition Buna-N or Viton ®
O-ring Buna-N or Viton ®
Spare sealing ring Teflon ®
Other components 300 series stainless steel
For more details, please refer to the following specification sheet.
Cleaning CGA 4.1 and ASTM G93
Yunlian Electrical Technical Support
yunlian technology support and quotation e-mail:njxj888@163.com
telephone:025-52791167,52791168
Fax:025-52791169
Phone :13390905858
mailbox:njxj888@163.com skype:yluedq
Address:Jiangning Shuanglong Avenue No.1222 Nanjing, Jiangsu. China P.O. 211100