Valve instruments

TESCOM pressure reducing valve

TESCOM调节阀26-1200

204

TESCOM regulating valve 26-1200

High flow Cv=3.3, 6.0 or 12.0

Maximum inlet pressure 6000 PSIG/Load external gas outlet pressure can reach maximum inlet pressure

Mouth pressure value/No exhaust valve/Reduced pressure

26-1200 series

technical specifications

Operating parameters

Pressure rating according to ANSI/ASME B31.3 standard

Maximum rated inlet pressure 4000&6000 PSIG

Export pressure To the maximum inlet pressure value

Design test pressure Maximum rated pressure 150%

Leakage No gas leakage

Rated flow rate Cv=3.3, 6.0 or 12.0*

*The secondary pressure drop caused by the outlet cross hole will have a significant impact on the rated flow rate.

For flow curve data when the outlet pressure is less than 1000 PSIG, please contact the engineer

Factory consultation.

Materials in contact with the medium

Valve body 303, 316 stainless steel, or 2024-T351 aluminum

Valve seat CTFE or Vespel ®

Partition Buna-N or Viton ®

O-ring Buna-N or Viton ®

Spare sealing ring Teflon ®

Other components 300 series stainless steel

For more details, please refer to the following specification sheet.

Cleaning CGA 4.1 and ASTM G93

 