Valve instruments

Product

Yokogawa YOLPGAWA pressure transmitter EJX510B

70
  • Style:横河 YOLPGAWA 压力变送器 EJX510B
  • Specifications:横河 YOLPGAWA 压力变送器 EJX510B
  • Online ordering

Yokogawa YOLPGAWA pressure transmitter EJX510B

The sealing diaphragm of the diaphragm sealed remote pressure transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component in the differential pressure transmitter. It is connected to the transmitter by a capillary filled with fluid. SC438W and SC438N (similar to EJA438W and EJA438N) diaphragm sealed pressure transmitters are used to measure the flow rate, liquid level, density, and differential pressure of liquids, gases, and vapors, and then output a 4-20mA DC signal corresponding to the measured differential pressure. It can also communicate with the manual operator and perform remote settings and monitoring

 

Detailed information on diaphragm sealed pressure transmitters:

 

1、 Standard technical specifications

 

1.1 Communication Line Conditions

 

Power supply voltage: 16.4~42V DC (16.4~30V DC)

 

Communication distance: 2km (using CEV cable)

 

Load capacitance: below 0.22 µ F

 

Load inductance: below 3.3mH

 

Distance from power cord: above 15cm

 

The input impedance of the receiving instrument connected to the receiving resistor is above 10k Ω at 2.4kHz.

 

1.2 Environmental temperature

 

General diaphragm sealed pressure transmitter: -40~85 ℃ (-40~185 ° F)

 

Diaphragm sealed pressure transmitter with digital gauge head: -30~80 ℃ (-22~176 ° F)

 

1.3 Working pressure (rated working pressure of flange: 2.7kPa abs or 20mmHg abs)

 

1.4 Impact of power supply voltage variation: ± 0.005%/V (21.6~32V DC, 350 Ω)

 

1.5 Installation: transmitter: 2-inch pipeline installation; Diaphragm seal: flange installation.

 

1.6 Installation flange specifications: The side of the ANSI flange in contact with the gasket shall be serrated (according to ANSI B16.5).

 

1.7 Waterproof structure: JIS C0920 anti immersion type (equivalent to IEC IP67 and NEMA 4X)

 

1.8 transmitter material: flange: JIS SUS14A; Flange bolts: refer to the “Model and Specification Code Table”

 

1.9 Diaphragm seal material: capillary tube: JIS SUS316; Protective tube: JIS SUS304; PVC shielding (PVC * * * usage temperature: 100 ℃)

 

1.10 Damping Time Constant: The sum of the time constants of the amplifier assembly and the diaphragm box assembly with a diaphragm seal (the time constant of the amplifier assembly is 0.2-64 seconds, which can be set in 9 stages; when the capillary length is 3m and the injected liquid code A is used, the value is obtained at normal temperature).

横河 YOLPGAWA 压力变送器 EJX510B
隔膜密封式远传压力变送器的密封隔膜是用于防止管道中的介质直接进入差压变送器里的压力传感器组件中,它与变送器之间是靠注满流体的毛细管连接起来的。SC438W、SC438N(与EJA438W、EJA438N一样)隔膜密封式压力变送器用来测量液体、气体和蒸汽的流量、液位、密度和差压,然后输出与测得的差压相对应的4~20mA DC信号。也可与手操器相互进行通信,可进行远程设定及监控等

隔膜密封式压力变送器的详细资料:

一、标准技术规格

1.1通信线路条件

电源电压:16.4~42V DC(16.4~30V DC)

通信距离:2km(使用CEV电缆)

负载电容:0.22µF以下

负载电感:3.3mH以下

与电源线的间距:15cm以上

连接于接收电阻上的接收仪表的输入阻抗在2.4kHz时,为10kΩ以上。

1.2环境温度

一般型隔膜密封式压力变送器:-40~85℃(-40~185?F)

带数字式表头隔膜密封式压力变送器:-30~80℃(-22~176?F)

1.3工作压力(法兰的额定工作压力:2.7kPa abs或20mmHg abs)

1.4电源电压变动的影响:±0.005%/V(21.6~32V DC,350Ω)

1.5安装:变送器:2inch管道安装;隔膜密封件:法兰安装。

1.6安装法兰规格:ANSI规格的法兰与垫片接触的一面,进行锯齿形加工(根据ANSI B16.5)。

1.7防水结构:JIS C0920防浸型(相当于IEC IP67和NEMA 4X)

1.8变送器材质:法兰:JIS SUS14A;法兰螺栓:参阅“型号及规格代码表”

1.9隔膜密封件材质:毛细管:JIS SUS316;保护管:JIS SUS304;PVC屏蔽(PVC的***使用温度:100℃)

1.10阻尼时间常数:放大器组件和带隔膜密封件的膜盒组建的时间常数相加值(放大器组建的时间常数:0.2~64秒,可分9段设定;当毛细管长3m,注入液的代码A时,在正常温度下取得值)。